FOURSTAR
IESW-1208
Wide-temperature rugged 8-port unmanaged industrial Ethernet switch with M12 interface. In line with IEEE802.3 and 10/100Base-TX industrial Ethernet standard; Protection grade: IP67; Network interface rate: 10/100M, self-adaptive; Broadcast storm suppression function; With power supply and Ethernet interface status indicators; Each network interfac..
IESW-3
Mini 3-port industrial Ethernet switch, also known as Ethernet bus connector and network tee. The size of a mahjong; Directly inserted into the network interface of the device to immediately expand the device's one network interface into two network interfaces to realize the "hand in hand" bus connection of Ethernet; Do not take up th..
IESW-8
Industrial-grade wide-temperature 8-port unmanaged industrial Ethernet switch. In line with IEEE802.3 and 10/100Base-TX industrial Ethernet standard; Network interface rate: 10/100M, self-adaptive; With broadcast storm suppression function; With power supply and Ethernet interface status indicators; Each network interface isolated from each other a..
IESW-8G
8-port kilomega looped network industrial Ethernet switch. In line with IEEE802.3 and 10/100/1000 Base-TX industrial Ethernet standard; Network interface rate: 1000M/100M/10M, self-adaptive; Support redundant topologies; Broadcast storm suppression function; With power supply and Ethernet interface status indicators; Each network interface isolated..
IOL-1000
IO-Link repeater long-line transceiver. Extend the IO-Link communication distance to 1000m; Divided into two modules, A and B, which are used in pairs; Communication rate: COM1 (4.8Kbps), COM2 (38.4Kbps), COM3 (230.4Kbps), self-adaptive; Support IO-Link, SIO, DI/DO, Class A interface, Class B interface and other working modes; Plug-and-play without..
IOL-300
IO-Link Repeater. No external power supply, use one to extend the maximum communication distance to 100 m and support SIO; use two to extend the maximum communication distance of IO-Link to 300 m without support SIO. Communication rate COM1(4.8kbps), COM2(38.4kbps), COM3(230.4kbps) adaptive, support IO-Link, SIO, DI/DO, port class A, port class B m..
ISO-IE1K
Industrial Ethernet isolation protector. Applicable for electrical isolation of Ethernet interfaces of various devices; Protect Ethernet devices and interfaces and eliminate interference caused by ground potential difference between both ends of communication; Lightning and surge protection; Support all communication protocols, such as Ethernet, Re..
LON-TR03
LonWorks universal network terminal matcher. In line with the LonMark standard; Applicable for TP/FT-10 (single-ended and dual-ended), TP/XF-78, TP/XF-1250 and other transceivers and topologies; Eliminate network signal reflections, reduce noise, increase network throughput, improve network reliability, reduce packet errors, and greatly improve Lon..
OMR-485
Mini RS232 to RS485/422 converter for OMRON PLC or touch panel. Compatible with and replacement of OMRON CJ1W-CIF11 and NS-AL002; Smaller size; More beautiful and classy when installed on PLC or touch screen. No external power supply required; No dip switch required to select the working mode; Non-isolated surge protection; Baud rate: 0-230Kbps, se..
PB-FO2T-M
Optical fiber PROFIBUS bus connector (multi-mode). 1-electrical 2optical; Single-fiber transmission; 180 degrees in-line mounting; Smaller size, suitable for narrow space; Achieve high-speed long-distance transmission of PROFIBUS signal; Completely solve the engineering problems such as electromagnetic interference, ground loop interference and lig..
PB-FO2T-S
Optical fiber PROFIBUS bus connector (single-mode). 1-electrical 2optical; Single-fiber transmission; 180 degrees in-line mounting; Smaller size, suitable for narrow space; Achieve high-speed long-distance transmission of PROFIBUS signal; Completely solve the engineering problems such as electromagnetic interference, ground loop interference and li..
PB-TR485
PROFIBUS active terminal resistor. Used as a replacement for a PROFIBUS site that may be subject to a power outage to avoid communication anomalies when the network loses the terminal resistance during a power outage at the site; 24VDC isolated power supply; With communication indicator; Standard lead rail mounting...
PC/MPI+
Siemens S7-300/400 PLC programming cable for isolated RS232 interface. USB/PPI isolation; 3m; With communication indicator; Alternatives to Siemens products: 6ES7 972-0CA23-0XA0; PC port communication rate: 19.2Kbps-115.2Kbps, self-adaptive; MPI port communication rates: 187.5Kbps and 19.2Kbps, self-adaptive; Can use PC/MPI+ to connect to the PLC t..
PC/PPI+
Optical isolation PC/PPI cable. Functions same as the above; Support 10-bit and 11-bit MODEM communication; With communication indicator; Baud rate: 0-115.2Kbps, self-adaptive; Maximum communication distance: up to 2km...
PC/TTY
Communication interface cable from RS232 to Siemens S5 series PLC programming interface (DB15). 3m; Corresponding Siemens product number: 6ES5 734-1BD20; RS232/electric current loop interface...